Thursday, April 03, 2008

Revit MEP Coordination Views

When you are using either a Mechanical or Electrical view disipline, the view will display those objects darker than the architectural objects or other MEP objects. You can see from this Mechanical 3D view below, the walls are light, and you can see the piping going through it.


If you change the view properties so it is displaying using a coordination disipline instead, the walls will become darker, and the piping will be hidden behind the wall objects. But it will not display the piping with hidden lines.


If you create plan views using Coordination disipline, you can see the pipe that goes through the wall or under a light fixture or another pipe as disappearing.


When in plan mode, and the view set to a mechanical disipline, you can see those pipes passing below other MEP objects as hidden lines, but not shown hidden through the wall objects as shown below.


To do this, you'd probably need to use a basic line tool for this. Perhaps there will be more control provided for this feature in the future. For now the above workaround may help.